INFRALAN® Cat.7A Installation Cable S/FTP 1500 MHz CPR Cca

Product features
Cable silicone free PoE Cable structure Category Conductor category Conductor material AWG-size/quantity of cores Diameter conductor Screen over stranding Stranding element Screen over stranding element Core insulation Core identification Material outer sheath Euro class Flame retardant Halogen free Halogen free (acc. EN 50267-2-2) Halogenfrei nach EN 60754-1/2 Low smoke (acc. EN 61034-2) Operating temperature, flexible Operating temperature, fix Operating temperature, storage Bending radius (dynamic) Bending radius (static) NVP value Loop resistance Resistance unbalance Dielectric strength DC Insulation resistance (500V) Capacity to earth Impedance Transfer impedance at 1MHz Transfer impedance at 10MHz Transfer impedance at 30MHz Transfer impedance at 100MHz Separation class acc. EN50174-2 Coupling attenuation Type Coupling attenuation Cabling standards Installation standard Harmonised Standard Directive/Regulation Transmission standards Cable Max. Freuqency
yes yes;PoE+;UPoE S/FTP 7A Kl.1 = single wire CU, tinned 22. Jan 0.64mm braiding pairs foil foam-skin PE colour FRNC Cca acc. EN 60332-1 acc. EN 60754-1/2 True yes yes 0 – 50°C -20 – 60°C 0 – 50°C ≥ 70mm ≥ 35mm 78% ≤ 120Ohm/km ≤ 2% 1kV/1 min ≥ 5000MOhm/km ≤ 1200pF/km 100 ± 5Ohm ≤ 5mOhm/m ≤ 5mOhm/m ≤ 5mOhm/m ≤ 10mOhm/m D Typ 1 ≥ 85dB ISO/IEC 11801;EN 50173-1 EN 50174 EN 50575 RoHS 2011/65/UE;REACH 1907/2006/EC IEEE 802.3 10Mbit bis 10Gbit IEC 61156-7;EN 50288-9-1 1500MHz

Article information

The INFRALAN® installation cable 99983.x-CPR is constructed for transmissions up to 1500 MHz and exceeds with the electrical transmission properties and requirements of the category 7A. Suitable for structured cabling of Class E, EA, F and FA according to ISO/IEC 11801 (AMD 2:2009) resp. EN 50173-1 (2009). The individual stranded pairs are protected with a screen foil (PiMF) and a total braided shield against radiation into the cable, as well as this excellent protection prevents the radiation of signals from the cable out. This shielding guarantees compliance with the interference emission according to Class B EN 55022, as well as immunity to interference according to EN 55024. The stranding of the individual pairs is optimized in such a way that the delay skew between the pairs (skew) with the greatest possible decoupling (crosstalk) is minimal. With this cable transmission rates up to 10 GBit according to IEEE 802.3 are possible.

Variants

Article No. Planers text Title Price (SRP) Length Colour outer sheath RAL colour Number of cores Type Outer diameter approx. Copper weight Weight Max. tractive force Fire load
999830.1-CPR INFRALAN® Cat.7A 1500 AWG22,S/FTP 4P ,CPR Cca,25Gbit/s ready,rape yellow RAL1021 1.0m yellow RAL1021 8 simplex 08. Junmm 38kg/km 75kg/km 190N 0.69MJ/m
999830.100-CPR INFRALAN® Cat.7A 1500 AWG22,S/FTP 4P CPR,Cca,25 GBit/s ready,rape yellow RAL1021 100.0m yellow RAL1021 8 simplex 08. Junmm 38kg/km 75kg/km 190N 0.69MJ/m
999830.500-CPR INFRALAN® Cat.7A 1500 AWG22,S/FTP 4P ,CPR Cca,25Gbit/s ready,rape yellow RAL1021 500.0m yellow RAL1021 8 simplex 08. Junmm 38kg/km 75kg/km 190N 0.69MJ/m
999830DX.500-CPR INFRALAN®Cat.7A 1500 AWG22,S/FTP,2x4P,CPR Cca,25Gbit/s ready,rape yellow RAL1021 500.0m yellow RAL1021 2x8 duplex 8.6x17.5mm 76kg/km 150kg/km 380N Jan 38MJ/m

Downloads